During the last 10 years more data has become available to validate the latest versions of the Program. Validation has been performed against small scale long flexible riser data. In general there is only a sparse amount of full scale riser data to validate against. Validation of the latest version of the Program, which has a particular emphasis on VIV suppression effects is available in OMAE 2011-49817 (Resvanis and Vandiver).
Key validation parameters are shown below:

Bare Riser Validation

Partial Strake Validation

Validation parameters

Validation parameters

Program Version:

4.6c issued 9:00am 20 January 2011

Program Version:

4.6c issued 9:00am 20 January 2011

Bare Riser St Code:

0.18

Bare Riser St Code:

0.18

Bare Riser Bandwidth:

0.4

Bare Riser Bandwidth:

0.4

Bare Riser CL Table #

1

Bare Riser CL Table #

1

Bare Riser Ca:

1.0

Bare Riser Ca:

1.0

Bare riser Hydrodynamic damping parameters:

0.2, 0.18, 0.2

Bare riser Hydrodynamic damping parameters:

0.2, 0.18, 0.2

 

 

Straked zone St Code;

0.100

0.10

 

 

Straked Riser Bandwidth:

0.25

0.25

 

 

Straked Riser CL Table #

5

 

 

Straked Riser Ca:

2.0

 

 

Straked riser Hydrodynamic damping parameters:

0.4, 0.5, 0.2

Power cutoff:

0.05

Power cutoff:

0.05

Amplitude cutoff

0.3

Amplitude cutoff

0.3

 